• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sat, 04.05.24

Search results


March 2014
Avraham Unterman, Anat Achiron, Itai Gat, Oren Tavor and Amitai Ziv
 Background: Physicians are often insufficiently trained in bedside teaching and mentoring skills. Objectives: To develop, implement and assess a simulation-based training program designed to improve clinical teaching among physicians.

Methods: We developed a one-day tutor training program based on six simulated scenarios with video-based debriefing. The program's efficacy was assessed using questionnaires completed by the participating physicians and their students. Main outcome measures were self-perceived teaching skills at baseline, after participation in the program, and following completion of the tutor role. Secondary outcome measures were the students' perceptions regarding their tutor skills.

Results: Thirty-two physicians (mean age 35.5, 56% females) participated in the program. Self-assessment questionnaires indicated statistically significant improvement following the program in 13 of 20 measures of teaching skills. Additional improvement was observed upon completion of the tutor role, leading to significant improvement in 19 of the 20 measures. Questionnaires completed by their students indicated higher scores in all parameters as compared to a matched control group of tutors who did not participate in the program, though not statistically significant. Most participants stated that the program enhanced their teaching skills (88%), they implement program-acquired skills when teaching students (79%), and they would recommend it to their peers (100%). Satisfaction was similar among participants with and without previous teaching experience.

Conclusions: A novel one-day simulation-based tutor training program was developed and implemented with encouraging results regarding its potential to improve clinical teaching and mentoring skills. 

July 2007
O.Tavor, M.Shohat and S.Lipitz

Background: The measurement of maternal serum human chorionic gonadotropin as a predictor of fetuses with Down syndrome has been in use since 1987.

Objectives: To determine the correlation between extremely high levels of hCG[1] at mid-gestation and maternal and fetal complications.

Methods: The study group consisted of 75 pregnant women with isolated high levels of hCG (> 4 MOM) at mid-gestation, and the control group comprised 75 randomly selected women with normal hCG levels (as well as normal alpha-fetoprotein and unconjugated estriol levels). The data collected included demographic details, fetal anomalies, chromosomal aberrations, pregnancy complications, and results of neonatal tests.

Results: There was a significant increase in the frequency of fetal anomalies (detected by ultrasound), low birth weight and neonatal complications in the study group. We also found an increased rate of fetal/neonatal loss proportional to the increasing levels of hCG (up to 30% in levels exceeding 7 MOM).

Conclusion: Our study demonstrated an increased frequency of obstetric complications that was closely associated with raised hCG levels. The study also raises questions about the accuracy of the Down syndrome probability equation in the presence of extremely high levels of hCG where data on the frequency of Down syndrome is severely limited.






[1] hCG = human chorionic gonadotropin


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel